Cartridge Fuse

Cartridge Fuse 5 x 20 mm

520.000
Feinsicherung 5x20mm sand ESKA
Fuse:
5 x 20 mm
Fuse-links Quick acting (F)
Voltage:
250 V
Current:
500 mA up to 20 A
Breaking capacity:
20 A up to 1.000 A
Approvals:
DIN 41571-1
CE Approbation RoHS Approbation

Features / Packaging unit

Features

Construction:
  • cylindrical
  • Glass tube with extinguishing agent
Contact caps:
Brass, nickel-plated
Solderability:
according to IEC 60068-2-20
As assembly with 2 pigtails of any shape and length, ready fitted

Packaging

  • 100 pcs = 10 boxes of 10 pieces each
  • 1.000 pcs = industrial packaging

Ratings

Part number Current Current Voltage drop (max [mV]) Sustained dissipation (max [W]) Breaking capacity Melting I2t [A2 s]
520.014 500 mA AC / DC 250 V 1.000 mV 2,5 W AC 80 A / DC 20 A 0,060 A²s
520.015 630 mA AC / DC 250 V 630 mV 2,5 W AC 80 A / DC 20 A 0,110 A²s
520.016 800 mA AC / DC 250 V 240 mV 2,5 W AC 80 A / DC 20 A 0,190 A²s
520.017 1 A AC / DC 250 V 200 mV 2,5 W AC 1.000 A / DC 250 A 0,300 A²s
520.018 1,25 A AC / DC 250 V 190 mV 2,5 W AC 1.000 A / DC 250 A 0,570 A²s
520.019 1,6 A AC / DC 250 V 480 mV 2,5 W AC 1.000 A / DC 250 A 0,650 A²s
520.020 2 A AC / DC 250 V 400 mV 2,5 W AC 1.000 A / DC 250 A 1,54 A²s
520.021 2,5 A AC / DC 250 V 400 mV 2,5 W AC 1.000 A / DC 250 A 2,73 A²s
520.022 3,15 A AC / DC 250 V 400 mV 2,5 W AC 1.000 A / DC 250 A 3,94 A²s
520.023 4 A AC / DC 250 V 240 mV 2,5 W AC 1.000 A / DC 250 A 13,3 A²s
520.024 5 A AC 250 V 240 mV 2,5 W AC 300 A 24,9 A²s
520.025 6,3 A AC / DC 250 V 230 mV 2,5 W AC 1.000 A / DC 250 A 43,3 A²s
520.026 8 A AC 250 V 170 mV 2,5 W AC 300 A 85,4 A²s
520.027 10 A AC 250 V 160 mV 2,5 W AC 300 A 195 A²s
520.028 12,5 A AC 250 V 150 mV 2,5 W AC 300 A 410 A²s
520.029 15 A AC 250 V 150 mV 2,5 W AC 300 A 888 A²s
520.030 16 A AC 250 V 130 mV 2,5 W AC 300 A 950 A²s
520.031 20 A AC 250 V 150 mV 4,0 W AC 300 A 2.100 A²s

Pre-arcing time limits

Rated current 2,1 lrat
min.max.
4 lrat
min.max.
10 lrat
min.max.
lrat
min.max.
500 mA – 16 A 30 min 300 ms 0 ms20 ms