Cartridge Fuse

Cartridge Fuse 6,3 x 32 mm

632.900
Feinsicherung 6,3x32mm glas ESKA
Fuse:
6,3 x 32 mm
Fuse-links Time-lag (T)
Voltage:
500 V
Current:
50 mA up to 2 A
Breaking capacity:
35 A
Approvals:
Factory standard
CE Approbation RoHS Approbation

Features / Packaging unit

Features

Construction:
  • cylindrical
  • Glass tube without extinguishing agent
Contact caps:
Brass, nickel-plated
Solderability:
according to IEC 60068-2-20
As assembly with 2 pigtails of any shape and length, ready fitted

Packaging

  • 100 pcs = 10 boxes of 10 pieces each
  • 500 pcs = industrial packaging

Ratings

Part number Current Current Voltage drop (max [mV]) Sustained dissipation (max [W]) Breaking capacity Melting I2t [A2 s]
632.904 50 mA AC 500 V 4.000 mV On request 35 A 0,0270 A²s
632.905 63 mA AC 500 V 3.500 mV On request 35 A 0,0180 A²s
632.906 80 mA AC 500 V 3.000 mV On request 35 A 0,0170 A²s
632.907 100 mA AC 500 V 2.500 mV On request 35 A 0,0800 A²s
632.908 125 mA AC 500 V 2.000 mV On request 35 A 0,156 A²s
632.909 160 mA AC 500 V 1.900 mV On request 35 A 0,258 A²s
632.910 200 mA AC 500 V 1.500 mV On request 35 A 0,454 A²s
632.911 250 mA AC 500 V 1.300 mV On request 35 A 0,55 A²s
632.912 315 mA AC 500 V 1.100 mV On request 35 A 0,88 A²s
632.913 400 mA AC 500 V 1.000 mV On request 35 A 0,61 A²s
632.914 500 mA AC 500 V 800 mV On request 35 A 2,56 A²s
632.915 630 mA AC 500 V 600 mV On request 35 A 3,23 A²s
632.916 800 mA AC 500 V 400 mV On request 35 A 6,55 A²s
632.917 1 A AC 500 V 300 mV On request 35 A 11,9 A²s
632.918 1,25 A AC 500 V 250 mV On request 35 A 15,8 A²s
632.919 1,6 A AC 500 V 200 mV On request 35 A 37,2 A²s
632.920 2 A AC 500 V 150 mV On request 35 A 29,2 A²s

Pre-arcing time limits

Rated current 1,15 lrat
min.max.
2,1 lrat
min.max.
2,75 lrat
min.max.
4 lrat
min.max.
10 lrat
min.max.
50 mA – 2 A 60 min 10 min 400 ms20 s 150 ms2 s 20 ms300 ms