Cartridge Fuse

Cartridge Fuse 5 x 20 mm

522.700
Feinsicherung 5x20mm keramik ESKA
Fuse:
5 x 20 mm
Fuse-links Time-lag (T)
Voltage:
250 V
Current:
100 mA up to 12,5 A
Breaking capacity:
1.500 A
Approvals:
IEC 60127-2/5
CE Approbation RoHS Approbation

Features / Packaging unit

Features

Construction:
  • cylindrical
  • 100 mA up to 500 mA: Ceramic tube without extinguishing agent
  • 630 mA up to 12,5 A: Ceramic tube with extinguishing agent
Contact caps:
Brass, nickel-plated
Solderability:
according to IEC 60068-2-20
As assembly with 2 pigtails of any shape and length, ready fitted

Packaging

  • 100 pcs = 10 boxes of 10 pieces each
  • 1.000 pcs = industrial packaging

Ratings

Part number Current Current Voltage drop (max [mV]) Sustained dissipation (max [W]) Breaking capacity Melting I2t [A2 s]
522.707 100 mA AC 250 V 2.800 mV 1,6 W 1.500 A 0,0500 A²s
522.708 125 mA AC 250 V 2.600 mV 1,6 W 1.500 A 0,0700 A²s
522.709 160 mA AC 250 V 2.400 mV 1,6 W 1.500 A 0,0970 A²s
522.710 200 mA AC 250 V 2.100 mV 1,6 W 1.500 A 0,107 A²s
522.711 250 mA AC 250 V 1.500 mV 1,6 W 1.500 A 0,508 A²s
522.712 315 mA AC 250 V 1.100 mV 1,6 W 1.500 A 0,580 A²s
522.713 400 mA AC 250 V 1.000 mV 1,6 W 1.500 A 0,740 A²s
522.714 500 mA AC 250 V 850 mV 1,6 W 1.500 A 1,70 A²s
522.715 630 mA AC 250 V 650 mV 1,6 W 1.500 A 0,390 A²s
522.716 800 mA AC 250 V 500 mV 1,6 W 1.500 A 0,850 A²s
522.717 1 A AC 250 V 350 mV 2,5 W 1.500 A 1,46 A²s
522.718 1,25 A AC 250 V 300 mV 2,5 W 1.500 A 2,30 A²s
522.719 1,6 A AC 250 V 200 mV 2,5 W 1.500 A 5,60 A²s
522.720 2 A AC 250 V 190 mV 2,5 W 1.500 A 12,1 A²s
522.721 2,5 A AC 250 V 180 mV 2,5 W 1.500 A 24,9 A²s
522.722 3,15 A AC 250 V 140 mV 4,0 W 1.500 A 48,8 A²s
522.723 4 A AC 250 V 100 mV 4,0 W 1.500 A 46,8 A²s
522.724 5 A AC 250 V 100 mV 4,0 W 1.500 A 101 A²s
522.725 6,3 A AC 250 V 100 mV 4,0 W 1.500 A 148 A²s
522.726 8 A AC 250 V 100 mV 4,0 W 1.500 A 520 A²s
522.727 10 A AC 250 V 100 mV 4,0 W 1.500 A 610 A²s
522.728 12,5 A AC 250 V 100 mV 4,0 W 1.500 A 424 A²s

Pre-arcing time limits

Rated current 1,5 lrat
min.max.
2,1 lrat
min.max.
2,75 lrat
min.max.
4 lrat
min.max.
10 lrat
min.max.
100 mA – 800 mA 60 min 30 min 250 ms80 s 50 ms5 s 5 ms150 ms
1 A – 3,15 A 60 min 30 min 750 ms80 s 95 ms5 s 10 ms150 ms
4 A – 12,5 A 60 min 30 min 750 ms80 s 150 ms5 s 10 ms150 ms